Siemens Nx 12 User Manual Pdf

View and Download Siemens NXAIR P instructions for installation, operation and maintenance online. Withdrawable Circuit Breaker Switchgear up to 15 kV Medium Voltage Metal-Clad Type with Insulated Bus. NXAIR P switch pdf manual download. Frequency Bandwidth: 5 12 MHz Selectable 2D Frequencies: 6.2, 8.0, 10.0 MHz Selectable THI (TEI) Frequencies: 7.3, 8.0, 9.4 MHz. Siemens Medical Solutions USA, Inc. The products/features mentioned in this document may not be commercially avail-able in all countries. Due to regulatory reasons, their future availability cannot. Siemens PLM Software recommends the following workflow when creating a wiring assembly. The flow of data from the logical design into the physical design, back to the logical design, and on to manufacturing, governs this process. The following is a general procedure. Your needs may require changes to this list. Your web browser must have JavaScript enabled in order for this application to display correctly. Nx tutorial pdf provides a comprehensive and comprehensive pathway for students to see progress after the end of each module. With a team of extremely dedicated and quality lecturers, nx tutorial pdf will not only be a place to share knowledge but also to help students get inspired to explore and discover many creative ideas from themselves.

dci
Siemens Nx 12 User Manual Pdf

Step 2: Setting Up NX Environment Variables for DCI

The NX DCI uses environment variables set by the NX installation.

If NX is installed on the same computer as PC-DMIS, then you may skip this step. If it is installed on a network (mapped drive), then you need to set the required environmental variables.

Siemens Nx 12 User Manual Pdf File

There are two ways to handle the installation of environment variables:

Method 1: Run PC-DMIS from an NX Command Prompt

The first method is to run PC-DMIS from an NX command prompt. Start the command prompt from the NX Tools->Command Prompt option under the Start->NX menus. You can now run PC-DMIS from the command line.

Method 2: Manually Set Environment Variables

The second method is to manually set the required environment variables to tell PC-DMIS where to find the NX license server and NX executable. Set the required environment variables as shown below:

  • UGS_LICENSE_BUNDLE=<bundle name> where <bundle name> is the bundle name found in the NX license file. The UGS_LICENSE_BUNDLE variable tells the NX license server which license bundle you have. The bundle names can be found in the NX license file on the PACKAGE lines. For example, if your license file showed PACKAGE NXPTNR100 ugslmd, you would set UGS_LICENSE_BUNDLE=NXPTNR100.

  • UGS_LICENSE_SERVER=28000@<server name>, where <server name> is the name of the NX license server.

  • UGII_BASE_DIR=<install path>, where <install path> is the full pathway to the NX install directory. For NX 8, the default path is C:Program FilesUGSNX8.

  • UGII_ROOT_DIR=<exe path>, where <exe path> is the full pathway to the root folder of the NX executable. The PC-DMIS NX DCI uses this environment variable to find the NX executable.

Pdf

For NX 8, this is the default path: C:Program FilesUGSNX8UGII

User Manual Template

For NX 11, this is the default path: C:Program FilesSiemensNX11.0NXBIN (Starting with NX 11, Siemens changed their directory structure.)

For NX 12, this is the default path: C:Program FilesSiemensNX12.0NXBIN

Siemens Nx 11

  • These environment variables are useful for debugging problems:

    • UGII_KEEP_SYSTEM_LOG=<tog1>, where <tog1> is either YES or NO. Each NX session creates a log file. If you set this variable to YES, the log file remains when you exit NX.

    • UGII_TMP_DIR=<temp path>, where <temp path> is the temporary directory that NX uses (usually, it is C:WindowsTEMPUGS). The log files are in this directory.

    • UGS_LICENSING_NOTE=<tog2>, where <tog2> is either 1 or 0. If you set this to 1, the software adds NX licensing messages to the log file.

    • UGII_FLEX_NOTE=<tog3>, where <tog3> is either ON or OFF. If you set this to ON, the software adds NX Flex licensing messages to the log file.

Siemens Nx 12